Something is not normal and it needs to be fixed.
Fire alarm panel trouble signal.
Some fire alarm panels may indicate the type of fire alarm trouble and its location.
There are three basic categories for fire alarm panel signals.
A fire alarm trouble signal is generally yellow and indicates there s an operational issue.
3 a trouble signal was an indication that some part of the fire alarm system was broken or off normal.
Trouble signals occur due to ground faults circuit problems battery faults or other failures within the system.
Trouble signal a trouble signal is typically designated by a yellow light and means that there is an operational issue.
It could be a loss of power.
Contacting your fire equipment service provider a certified fire alarm technician or a qualified electrician would be the prudent thing to do.
The reset button only resets the panel after a fire alarm.
Many of the messages you see displayed here indicate a fault with your system that may require immediate attention and service.
Another signal is the trouble signal or trouble condition.
Here are some of the common reasons for a trouble signal.
Here s an explanation of what each fire alarm panel signal means.
If this does not work you ll need a service call so that a trained technician can assess and fix the problem.
At this point the system will send a signal to the central station and clear your communication failure.
Some wiring from the control panel to the devices in the house is supervised for integrity.
Trouble supervisory and alarm.
It means that something in the fire alarm is broken.
So it could be oh gosh it could be an open circuit where a wire s broken and we don t have a continuous electrical pathway back to the panel.
When fire alarm panels are in trouble condition it can be difficult to find the root cause of the problem.
Watch this video as orr vp of engineering lee kaiser walks us through the common causes for many trouble signals and the.
Fire alarm trouble signal.
Potter electric signal company is a st.
It will not reset any trouble.
With any of these signals most fire panels will also have a digital display that will tell you what type of signal is active.
For some more advanced systems the panel may indicate the kind of problem and where it is located.
A trouble signal will also have a yellow light or led lit on the fire panel and there will be a slower beeping tone sounding from the panel.
Louis missouri based manufacturer of sprinkler monitoring devices fire alarm systems and corrosion solution products.
The thing is having worked with a lot of fire alarm panels you know that a panel showing a trouble is a panel indicating that something is wrong with the fire alarm system.
Common fire alarm trouble indications.